TI AFE4900可穿戴无线多参数病人监护器参考设计TIDA-01580

来源: 中电网
2018-07-20
类别:健康医疗
eye 245
文章创建人 拍明

原标题:TI AFE4900可穿戴无线多参数病人监护器参考设计TIDA-01580

  TI公司的AFE4900是超低功耗集成模拟前端(AFE),用于同步化心电图(ECG)和光电血管容积图(PPG)信号收集,也可用于光生物检测应用如心率监测(HRM)和外周血氧饱和度(SpO2).同步PPG和ECG信号采集数据速率高达1kHz,PPG接收器动态范围高达100 dB.本文介绍了AFE4900主要特性和框图,以及采用AFE4900的可穿戴无线多参数病人监护器参考设计TIDA-01580主要特性,框图,电路图,材料清单和PCB设计图.

  The AFE4900 device is an analog front-end (AFE) forsynchronized electrocardiogram (ECG),photoplethysmogram (PPG) signal acquisition. Thedevice can also be used for optical bio-sensingapplications, such as heart-rate monitoring (HRM)and saturation of peripheral capillary oxygen (SpO2).

  The PPG signal chain supports up to four switchinglight-emitting diodes (LEDs) and up to threephotodiodes (PDs). The LEDs can be switched onusing a fully integrated LED driver. The current fromthe photodiode is converted into voltage by thetransimpedance amplifier (TIA) and digitized using ananalog-to-digital converter (ADC). The ECG signal chain has an instrumentation amplifier (INA) with aprogrammable gain that interfaces to the same ADC.

  A right-leg drive (RLD) amplifier set can be used tothe bias for the ECG input pins. AC and dc lead-offdetect schemes are supported. The ADC codes fromthe PPG and ECG phases can be stored in a 128-sample first in, first out (FIFO) block and read outusing either an I2C or a serial programming interface(SPI) interface.

  AFE4900主要特性:

  • Synchronized PPG, ECG Signal Acquisition atData Rates Up to 1 kHz

  • ECG Signal Chain:

  – Standalone ECG Acquisition Up to 4 kHz

  – Input Bias: 1-Lead ECG With RLD Bias

  – Programmable INA Gain: 2 to 12

  – Input Noise (1 Hz to 150 Hz): 2.5 μVrms at1 kHz, 1.25 μVrms at 4-kHz Data Rate

  – AC, DC Lead-Off Detect: 12.5-nA to 100-nA

  • PPG Receiver:

  – Supports Three Time-Multiplexed PD Inputs

  – 24-Bit Representation of Current From PD

  – DC Offset Subtraction DAC (Up to ±126-μA) atTIA Input for Each LED, Ambient

  – Digital Ambient Subtraction at ADC Output

  – Noise Filtering With Programmable Bandwidth

  – Transimpedance Gain: 10 kΩto 2 MΩ

  – Dynamic Range Up to 100 dB

  – Receiver Operates in PPG-Only mode atApproximately 1-μA/Hz Sampling Rate

  – Power-Down Mode: Approximately 0 μA

  • PPG Transmitter:

  – Four LEDs in Common Anode Configuration

  – 8-Bit LED Current Up to 200 mA

  – Mode to Fire Two LEDs in Parallel

  – Programmable LED On-Time

  – Simultaneous Support of Three LEDs forSpO2, or Multiwavelength HRM

  – Average Current of 30 μA Adequate for aTypical Heart-Rate Monitoring Scenario:

  – 20-mA Setting, 60-μs Pulse Duration,25-Hz Sampling Rate

  • Clocking Using an External or Internal Clock

  • FIFO With 128-Sample Depth for ECG and PPG

  • I2C, SPI™ Interfaces: Selectable by Pin

  • Operating Temperature Range: –20℃ to +70℃

  • 2.6-mm × 2.1-mm, 0.4-mm Pitch DSBGA Package

  • Supplies:

  – Rx: 1.8 V to 1.9 V (LDO Bypass),

  2.0 V to 3.6 V (LDO Enabled)

  – Tx: 3 V to 5.25 V

  – IO: 1.7 V to Rx_SUP

  AFE4900应用:

  • Synchronized PPG, ECG for Blood PressureEstimation

  • HRM for Wearables, Hearables

  • Heart-Rate Variability (HRV)

  • Pulse Oximetry (SpO2) Measurements

  可穿戴无线多参数病人监护器参考设计TIDA-01580

  TIDA-01580 Wearable, Wireless, Multi-Parameter Patient Monitor Reference Design This reference design is a simple, wearable, multiparameter,patient monitor that uses a single-chip,biosensing front end, the AFE4900 device, forsynchronized electrocardiography (ECG) andphotoplethysmography (PPG) measurements. Themeasured data is transferred to a remote locationusing the CC2640R2F device (supporting BLE 4.2 and5). The reference design is operated using a singleCR3032 battery and provides a battery life of 30 days.

  The raw data is available for the user to calculateheart rate, oxygen concentration in blood (SpO2),pulse-transit time (PTT), and ECG. Two onboard lightemittingdiodes (LEDs) indicate low-battery detectionand ECG lead-off detection for users.

  病人监护器参考设计TIDA-01580主要特性:

  • Simple, Wearable, Multi-Parameter, Patient Monitorfor PPG and ECG

  • Provides Raw Data to Calculate Heart Rate, SpO2,and PTT

  • Uses Single-Chip, Biosensing Front-End AFE4900Device for Synchronized ECG and PPGMeasurements

  – PPG (Optical Heart-Rate Monitoring and SpO2)Supports Four LEDs and Three Photodiodes(PDs), With Digital Ambient Subtraction toImprove Signal-to-Noise Ratio (SNR)

  – ECG (LEAD I) Signals

  • Integrated Arm® Cortex®-M3 and 2.4-GHz RFTransceiver (CC2640R2F) Supports Wireless DataTransfer – BLE 4.2 and 5.0

  • Operated By CR3032 (3-V, 500-mA Coin-CellBattery), With Battery Life of 30 Days Using HighlyEfficient DC/DC Converters

  • Small Form Factor Helps With Easy Adaptation toWearable Applications

  病人监护器参考设计TIDA-01580应用:

  • Wireless Patient Monitor

  • ECG

  • Pulse Oximeter

  • Wearable Fitness and Activity Monitor

病人监护器参考设计TIDA-01580外形图

  图.病人监护器参考设计TIDA-01580外形图

.病人监护器参考设计TIDA-01580 PCB顶视图

  图.病人监护器参考设计TIDA-01580 PCB顶视图(无电池夹头)

病人监护器参考设计TIDA-01580 PCB底视图

  图.病人监护器参考设计TIDA-01580 PCB底视图

  病人监护器参考设计TIDA-01580材料清单:

  详情请见:

afe4900.pdf

tidrw34.zip

tidudo6.pdf


责任编辑:HanFeng

【免责声明】

1、本文内容、数据、图表等来源于网络引用或其他公开资料,版权归属原作者、原发表出处。若版权所有方对本文的引用持有异议,请联系拍明芯城(marketing@iczoom.com),本方将及时处理。

2、本文的引用仅供读者交流学习使用,不涉及商业目的。

3、本文内容仅代表作者观点,拍明芯城不对内容的准确性、可靠性或完整性提供明示或暗示的保证。读者阅读本文后做出的决定或行为,是基于自主意愿和独立判断做出的,请读者明确相关结果。

4、如需转载本方拥有版权的文章,请联系拍明芯城(marketing@iczoom.com)注明“转载原因”。未经允许私自转载拍明芯城将保留追究其法律责任的权利。

拍明芯城拥有对此声明的最终解释权。

相关资讯